SolidFlow is a sensor especially developed for measuring the flow rate of solids conveyed in metallic ducts. It has successfully been tested for online-measuring of:
- types of dust, types of powder, granulates
- grain size between 1 nm and 1 cm
- pneumatically conveyed materials
- in free fall after mechanical conveying systems
|
Sensor/Sensor accommodation |
Housing |
|
stainless steel 1.4541
or galvanised Steel St 52 |
Protection category |
|
IP65, Dust EX 20 (option) |
Operating temperature |
|
front end of sensor: |
-20°C ... |
+80°C |
optional: |
-20°C ... |
+200°C |
sensor electronic: |
0°C ... |
+60°C |
|
max. working pressure |
|
1 bar, optional 10 bar |
Working frequency |
|
K-Band 24,125 GHz, ±100 MHz |
Transmitting power |
|
Max. 5 mW |
Weight |
|
Approx. 1.3 kg |
Dimension |
|
Ø 60, Ø 20, L 290 mm |
Accuracy |
|
+/- 2...5% in calibrated range |
 |
 |
 |
Evaluation-Unit |
|
|
Supply voltage |
|
110/240 V, 50 Hz |
Power consumption |
|
20W, 24 VA |
Current consumption |
|
Max. 1 A @ 24 V |
Protection category |
|
IP65 to EN 60 529/10.91 |
Operating temperature |
|
-10 … +45 °C [14...113 °F] |
Enclosure dimensions |
|
258 x 237 x 174 mm (W x H x D) |
Weight |
|
approx. 2.5 kg |
Cable glands |
|
3 x M16 (4.5-10 mm Ø) |
Screw terminals |
|
0,2-2,5 mm² [AWG 24-14| |
Current output signal
Voltage output signal |
|
4 … 20 mA (0 … 20 mA), Load < 700
2 … 10 V (0 … 10 V), Bürde > 2 kOhm |
measurement value alarm relay output |
|
Relay with switching contact
Max. 250V AC, 1A |
Data storage |
|
Flash |
Pulse output |
|
Open Collector / Max. 30V, 20mA |
 |
 |
 |
C-Box |
|
|
Dimensions |
|
98 x 64 x 35 mm (B x H x T) |
|
|
|
|
|
|
|
|
|
|
|
DensFlow
Mechanical conveying
Large flow rates are frequently realized with mechanical conveying systems, as for example air chutes or screw feeders.
DensFlow measures the flow rate directly after the outlet of the conveying system. |
DensFlow - Technical Data
Sensor pipe |
Housing |
|
Steel St 52, powder-coated
(optional Stainless steel 1.4541
NW 10…150( greater diameters on demand), Flange DIN 2576 |
Inner pipe |
|
POM, PTFE |
Protection category |
|
IP65 |
Operating temperature |
 |
|
Max. working pressure |
|
5 bar, optional 25 bar |
Working frequency |
|
100 kHz |
Weight |
|
Depending from the nominal value |
Dimension |
|
length 500 mm |
Accuracy |
|
± 2…5 % in calibrated range |
 |
 |
 |
Evaluation unit |
Supply voltage |
|
24 V DC |
Supply voltage |
|
12 W |
Protection category |
|
IP65 according to EN 60 529/10.91 |
Dimension |
|
19"-rack system
3HE, 28TE, L 227 mm |
Weight |
|
approx. 0,7 kg |
Input |
|
2 x Velocity
0…20 mA od 0…10 V
1 x Velocity 0…20 mA |
Connection |
|
Connector (DIN 41612) |
Connector |
|
Flow rate: 4 … 20 mA
Velocity: 4 … 20 mA
Density: 4 … 20 mA
Load < 500 Ohm |
Serial output |
|
either RS 232 or 485
MOD-Bus-Protokoll
sub-D 9-wired connector |
wired connector |
|
LCD-Display, lighted,
16 x 2 Digits, 4 x Push button |
Data protection |
|
EEPROM |
|
|
|
|
|
|
|
|
|
|
|
|
FlowJam
The microwave detector for the contactless monitoring of bulk materials for flow or no-flow.
Problem-free using with all bulk materials. |
FlowJam - Technical Data
Technical Data |
Housing |
|
Stainless steel 1.4541 |
Protective system |
|
IP 65 |
Max. ambient temperature |
|
-20°C ... 60°C |
Weight |
|
1,0 kg |
Power supply |
|
12 – 30 V
DC -0/+15%
12 – 24 V
AC -0/+15% |
Measuring frequency |
|
24.125 GHz
+/-100 MHz |
Detection range |
|
ca. 0 … 2 m |
Relay output max.: |
|
42 V AC/DC
2 A AC/DC
50 W/60 VA |
|
|
|
|
|
|
|
|
|