Thermal Mass Flow Meter
Model: THF Series
Mass Flowmeters with or without LCD Display |
- Accuracy: ±1% of full scale including linearity
- Repeatability: ±0.15% full scale or better
- Turndown Ratio: 100:1
- Response Time: 1 second
- Gas Ambient Temperature: 0 to 60°C
- Temperature Coefficient: 0.05% full scale per 1°C or better
- Pressure Coefficient: 0.01% full scale per PSI or better
- Minimum Pressure Requirements: Meters: 1 inch of H2O
- Maximum Gas Pressure: 500psi–SS316
- Leak integrity: 1 x10-6 cc⁄min of He or better
- Wetted Parts: 316 SS, Viton® O-rings
- Connections: 1⁄2” NPT(F) standard
- Input/Output Connection: 9-pin sub-D connector
- Output signal: Linear 0-5 Vdc,1000 ohms min load, 4-20 mA, 500 ohms loop resistance
- Input Power: Meters: 24 Vdc @ 300 mA, 115 Vac, 220 Vac with ac adaptor
- Weight: 2.6 kg with power supply
|
|
|
|
|
|
|
|
|
|
|
Model: TMF Series
Mass Flowmeters with or without LCD Display |
- Accuracy: ±1% of full scale including linearity
- Repeatability: ±0.15% full scale or better
- Turndown Ratio: 100:1Response Time: 1 second
- Gas Ambient Temperature: 0 to 60°C
- Temperature Coefficient: 0.05% full scale per 1°C or better
- Pressure Coefficient: 0.01% full scale per PSI or better
- Minimum Pressure Requirements: Meters: 1 inch of H2O
- Maximum Gas Pressure: 500psi–SS316
- Leak integrity: 1 x10-6 cc⁄min of He or better
- Wetted Parts: 316 SS, Viton® O-rings
- Connections: 1/2” NPT(F), standard
- Input/Output Connection: 9-pin sub-D connector
- Output signal: Linear 0-5 Vdc,1000 ohms min load, 4-20 mA, 500 ohms loop resistance
- Input Power: Meters: 24 Vdc @ 300 mA, 115 Vac, 220 Vac with ac adaptor
- Weight: 1.8 kg with power supply
|
|
|
|
|
|
|
|
|
|
|
Model: TSF Series
Mass Flowmeters with or without LCD Display |
- Accuracy: ±1% of full scale including linearity
- Repeatability: ±0.15% full scale or better
- Turndown Ratio: 100:1
- Response Time: 1 second
- Gas Ambient Temperature: 0 to 60°C
- Temperature Coefficient: 0.05% full scale per 1°C or better
- Pressure Coefficient: 0.01% full scale per PSI or better
- Minimum Pressure Requirements: Meters: 1 inch of H2O
- Maximum Gas Pressure: 500psi–SS316
- Leak integrity: 1 x10-6 cc⁄min of He or better
- Wetted Parts: 316 SS, Viton® O-rings
- Connections: 3⁄4” NPT(F), standard
- Input/Output Connection: 9-pin sub-D connector
- Output signal: Linear 0-5 Vdc,1000 ohms min load, 4-20 mA, 500 ohms loop resistance
- Input Power: Meters: 24 Vdc @ 300 mA, 115 Vac, 220 Vac with ac adaptor
- Weight: 6.8 kg with power supply
|
|
|
|
|
|
|
|
|
|
|
Model: TLFC Series
Mass Flow Controllers with or without LCD Display |
- Accuracy: ±1% of full scale including linearity
- Repeatability: ±0.15% full scale or better
- Turndown Ratio: 100:1
- Response Time: 1 second
- Gas Ambient Temperature: 0 to 60°C
- Temperature Coefficient: 0.05% full scale per 1°C or better
- Pressure Coefficient: 0.01% full scale per PSI or better
- Minimum Pressure Requirements: Meters: 1 inch of H2O
- Maximum Gas Pressure: 500psi–SS316
- Leak integrity: 1 x10-6 cc⁄min of He or better
- Wetted Parts: 316 SS, Viton® O-rings
- Connections: 1⁄4” NPT(F), standard
- Input/Output Connection: 9-pin sub-D connector
- Output signal: Linear 0-5 Vdc,1000 ohms min load, 4-20 mA, 500 ohms loop resistance
- Input Power: Meters: 24 Vdc @ 300 mA, 115 Vac, 220 Vac with ac adaptor
- Weight: 1.25 kg (2.75 lb) with power supply
|
|
|
|
|
|
|
|
Do you have any questions about our products? We will assist you selecting the right product for your application. Contact :Call +66 (0)8 5481 5915